| Operational AC Input Voltage |
Single Unit: 104-127 VAC @ 6 A; Dual Unit: 104-127 VAC @ 12 A; 47-63 |
| Switching Frequency |
Nominal 100 kHz |
| Voltage Mode Transient Response Time |
< 500 mks recovery to 50 mV band for ±50% load change in the range of 25% to 100% of rated load |
| Operating Temperature Range |
0 to 30 °C for full rated output. Above 30 °C, derate output linearty to zero at 70 °C |
| Storage Temperature Range |
- 55 to 85° C |
| Humidity Range |
0 to 80 % RH, non-condensing |
| Front Panel Voltage and Current Control |
10-turn voltage and current potentiometers |
| Front Panel Voltage and Current Resolution |
0.02% of maximum voltage |
| AC Input Connector Type |
IEC 320 Connector |
| Weight |
Approximately 3.5 kg (7.7 lb.) |
| Approvals |
CE-marked units meet standards: EN55011(Group Class A), EN50081-2, EN50082-1, and IEC 1010-1, NRTL/C, CSA certified |
| ANALOG PROGRAMMING |
|
| Remote On/Off and Interlock |
2-25 V signal or TTL-compatible input, selectable logic |
| Remote Analog Programming |
0-10 VDC for 0-100% of rated voltage or current ±1.0%, 0-10 kOhm for 0-100% of rated voltage or current ±1.0% |
| Remote Monitoring |
0-10 VDC for 0-100% of rated voltage or current ±1.0% |
| Over Voltage Protection Trip Range |
3V to full output + 10% |
| Tracking Accuracy |
±1% for series operation |
|
|
| HPD 300 W options |
|
| GPIB-HPD |
GPIB Interface Card(16-bit) |
| RS-232-HPD |
RS-232 Interface Card(16-bit) |
| APG-HPD |
Analog programming interface card |
| M2 |
200-250 VAC Input(50/60 Hz) |
| M2S |
Switch selectable input 110 VAC or 220 VAC |
| M11 |
10-turn current potentiometer |
| M13A |
Locking knobs for front panel control |
| RM-XHS |
19-inch rack mount kit for up to 4-HPD, XPD or XT power supplies |