Description
Model | XFR 150-8 |
|
| Output Ratings |
| Output Voltage, V | 0-150 | Output Current, A | 0-8 | Output power, W | 1200 |
|
| Line Regulation |
| Voltage, mV (0,01% of Vmax + 2 mV) | 17 | Current, mA (0,01% of Imax + 2 mA) | 2,8 |
|
| Load Regulation |
| Voltage, mV (0,02% of Vmax + 5 mV) | 35 | Current, mA (0,02% of Imax + 5 mA) | 6,6 |
|
| Meters accuracy |
| Voltmeter, mV (0,5% от Vmax) | 0,9 | Ampermeter, mA(0,5% от Imax) | 0,05 |
|
| Output noise & ripple |
| Voltage(rms), mV | 7 | Voltage, mV (0-20MHz) | 60 | Current(rms), mA | 3 |
|
| Drift (8 hours) |
| Voltage, mV (0,05% of Vmax) | 75 | Current, mA (0,05% of Imax) | 4 |
|
| Temperature Coefficient |
| Voltage, mV (0.02% of Vmax/°C) | 30 | Current, mA (0.03% of Imax/°C) | 2,4 |
|
| Program Slew Rate |
| Rise Time, ms | 170 | Fall Time, ms | 170 |
|
| OVP Adjustment Rate |
| V (5 to 110% of Vmax) | 7,5-165 |
|
| Efficiency, % | 87 |
Price: Contract price
|
|