Operational AC Input Voltage |
Single Unit: 104-127 VAC @ 6 A; Dual Unit: 104-127 VAC @ 12 A; 47-63 |
Switching Frequency |
Nominal 100 kHz |
Voltage Mode Transient Response Time |
< 500 mks recovery to 50 mV band for ±50% load change in the range of 25% to 100% of rated load |
Operating Temperature Range |
0 to 30 °C for full rated output. Above 30 °C, derate output linearty to zero at 70 °C |
Storage Temperature Range |
- 55 to 85° C |
Humidity Range |
0 to 80 % RH, non-condensing |
Front Panel Voltage and Current Control |
10-turn voltage and current potentiometers |
Front Panel Voltage and Current Resolution |
0.02% of maximum voltage |
AC Input Connector Type |
IEC 320 Connector |
Weight |
Approximately 3.5 kg (7.7 lb.) |
Approvals |
CE-marked units meet standards: EN55011(Group Class A), EN50081-2, EN50082-1, and IEC 1010-1, NRTL/C, CSA certified |
ANALOG PROGRAMMING |
|
Remote On/Off and Interlock |
2-25 V signal or TTL-compatible input, selectable logic |
Remote Analog Programming |
0-10 VDC for 0-100% of rated voltage or current ±1.0%, 0-10 kOhm for 0-100% of rated voltage or current ±1.0% |
Remote Monitoring |
0-10 VDC for 0-100% of rated voltage or current ±1.0% |
Over Voltage Protection Trip Range |
3V to full output + 10% |
Tracking Accuracy |
±1% for series operation |
|
|
HPD 300 W options |
|
GPIB-HPD |
GPIB Interface Card(16-bit) |
RS-232-HPD |
RS-232 Interface Card(16-bit) |
APG-HPD |
Analog programming interface card |
M2 |
200-250 VAC Input(50/60 Hz) |
M2S |
Switch selectable input 110 VAC or 220 VAC |
M11 |
10-turn current potentiometer |
M13A |
Locking knobs for front panel control |
RM-XHS |
19-inch rack mount kit for up to 4-HPD, XPD or XT power supplies |