XKW 1 kW General Specifications

Operational AC Input Voltage 200-250 VACat 10 Arms 1f, or 100-130 VAC at 20 Arms 1 f 47-63 Hz
Switching Frequency Nominal 100 kHz, 200 kHz ouput ripple (> 80 V models=80 kHz, 160 kHz ouput ripple)
Time Delay 2s maximum from on until ouput stable
Voltage ModeTransient Response Time < 1 ms recovery to 1% band for 30% step load change from 70% to 100% or 100% to 70%
Maximum Voltage Differential ±600 VDC from output to safety ground
Remote On/Off and Interlock TTL-compatatible input; Contact Closure 12-250 VAC or 12-130 VDC
Remote Analog Programming Voltageand current programming inputs (source must be isolated): 0-5kresistances; 0-5 V (default), 0-10 V voltage sources; 0-1 mA sources.OVP programming 0-5 V, 0-10 V voltage sources
Remote Monitoring Output voltage and current: 0-5 V. Zero to full scale output 1% accuracy
Maximum Remote Sense Line Drop Compensation 1 V/line (line drop is subtracted from total voltage available at supply output
Operating Temperature Range 0 to 50° C
Storage Temperature Range -55 to 85° C
Humidity Range 0 to 80% RH, non condensing
Front Panel Voltage and Current Control 10-turn voltage and current potentiometers
AC Input Connector Type Barrier strip #6 screw with cover
Main Output Connector Nickel-plated copper bus bars
Weight (one unit) Approximately 8,2 kg
Approvals CE-markedunits comply with the general protection requirements of the EuropeanEMC Directive, 89/336/EEC: EN55011 Group 1, Class A, EN50081-2,EN50082-1 and with the European LV Directive 72/23/EEC: IEC 1010-1, IEC1010-2, SCA certified

Electrical specifications and additional characteristics for the XKW 1000 Watt Series.

Model XKW 8-125 XKW 20-50 XKW 33-33 XKW 40-25 XKW 60-18 XKW 80-13 XKW 150-7 XKW 300-3,5 XKW 600-1,7

Output Ratings

Output voltage, V 0-8 0-20 0-33 0-40 0-60 0-80 0-150 0-300 0-600
Output Current, A 1-125 0-50 0-33 0-25 0-18 0-13 0-7 0-3,5 0-1,7
Output Power, W 1000 1000 1000 1000 1080 1040 1050 1050 1020

Line Regulation

Voltage, mV 1 1,5 1,5 3 3 3 5 10 20
Current, mA 10 5 3 2 2 2 1 1 1

Load Regulation

Voltage, mV 3 3 3 5 5 5 5 10 20
Current, mA 20 5 5 5 5 5 5 2 1

Meter Accuracy

Voltage (0,5% of Vmax + 1 count), V 0,05 0,2 0,3 0,3 0,4 0,5 0,9 3 4
Current (0,5% of Imax + 1 count), A 0,7 0,4 0,3 0,2 0,1 0,08 0,05 0,03 0,01

Output Noise & Ripple

Voltage rms, mV 7,5 5 5 5 5 5 15 15 75
Voltage p-p (20 Hz-20MHz), mV 60 60 60 60 60 60 175 175 500

Analog Programming Accuracy

Voltage (1% of Vmax), mV 80 200 330 400 600 800 1500 3000 6000
Current (1% of Imax), mA 1250 500 330 250 180 130 70 35 17

Drift (8 hours)

Voltage (0,05% of Vmax) 4 10 16,5 20 30 40 75 150 300
Current (0,03% of Imax) 62,5 25 16,5 12,5 9 6,5 3,5 1,75 0,85

Temperature Coefficient

Voltage(0,02% of Vmax/єC) 1,6 4 6,6 8 12 16 30 60 120
Current(0,03% of Imax/єC) 37,5 15 9,9 7,5 5,4 3,9 2,1 1,05 0,51

OVP Adjustment Range

(5% to 110% of Vmax) 0,4-8,8 1 - 22 1,65-36,3 2-44 3-66 4-88 7,5-165 15-330 30-660