  HPD 300 W Series General Specifications
rus eng  
Operational AC Input Voltage Single Unit: 104-127 VAC @ 6 A; Dual Unit: 104-127 VAC @ 12 A; 47-63
Switching Frequency Nominal 100 kHz
Voltage Mode Transient Response Time < 500 mks recovery to 50 mV band for ±50% load change in the range of 25% to 100% of rated load
Operating Temperature Range 0 to 30 °C for full rated output. Above 30 °C, derate output linearty to zero at 70 °C
Storage Temperature Range - 55 to 85° C
Humidity Range 0 to 80 % RH, non-condensing
Front Panel Voltage and Current Control 10-turn voltage and current potentiometers
Front Panel Voltage and Current Resolution 0.02% of maximum voltage
AC Input Connector Type IEC 320 Connector
Weight Approximately 3.5 kg (7.7 lb.)
Approvals CE-marked units meet standards: EN55011(Group Class A), EN50081-2, EN50082-1, and IEC 1010-1, NRTL/C, CSA certified
ANALOG PROGRAMMING
Remote On/Off and Interlock 2-25 V signal or TTL-compatible input, selectable logic
Remote Analog Programming 0-10 VDC for 0-100% of rated voltage or current ±1.0%, 0-10 kOhm for 0-100% of rated voltage or current ±1.0%
Remote Monitoring 0-10 VDC for 0-100% of rated voltage or current ±1.0%
Over Voltage Protection Trip Range 3V to full output + 10%
Tracking Accuracy ±1% for series operation


HPD 300 W options
GPIB-HPD GPIB Interface Card(16-bit)
RS-232-HPD RS-232 Interface Card(16-bit)
APG-HPD Analog programming interface card
M2 200-250 VAC Input(50/60 Hz)
M2S Switch selectable input 110 VAC or 220 VAC
M11 10-turn current potentiometer
M13A Locking knobs for front panel control
RM-XHS 19-inch rack mount kit for up to 4-HPD, XPD or XT power supplies