Технические характеристики HPD
Models (V-A) |
HPD 15-20 |
HPD 30-10 |
HPD 60-5 |
Output Voltage Output Current Output Power |
0-15V 0-20A 300W |
0-30V 0-1OA 300W |
0-60V 0-5A 300W |
Line Regulation: Voltage (0.01% of Vmax+2mV) Current (0.01% of lmax+1mA) |
3.5mV 3mA |
5mV 2mA |
8mV 1.5mA |
Load Regulation: Voltage (0.01% of Vmax+2mV) Current (0.01% of lmax+1mA) |
3.5mV 3mA |
5mV 2mA |
8mV 1.5mA |
Meter Accuracy: Voltage (1 % of V max +1 count) Current (1% of lmax+ 1 count) |
0.25V 0.3A |
0.4V 0.2A |
0.7V 0.06A |
Output Noise and Ripple at rear output (20Hz-20MHz) |
5mVrms lOOmVp-p |
5mVrms lOOmVp-p |
5mVrms lOOmVp-p |
Stability:'' Voltage (0.02% of V max) Current (0.03% of 1 max) |
3mV 6mA |
6mV 3mA |
12mV 1.5mA |
Temperature Coefficient:Voltage (0.015% of Vmax/°C) Current (0.02% of lmax/°C) |
2.25mV 4mA |
4.5mV 2mA |
9mV 1mA |
Front Panel Voltage Control Resolution (0.02% of V max) |
3mV |
6mV |
12mV |
см.также XT серию |
© 2000 Омником Все права защищены
109004, г.Москва, Пестовский пер., д. 16, стр. 2, тел.: (095) 742-10-63, факс: (095) 915-70-10
e-mail:info@omnicom.ru
|
|